Battery Analyzers
View Large
Product Name : Battery Analyzers
Product Origin : Hong Kong S.A.R., China
Product Category : Others
More Products : Click here!
Contact Details : 運揚有限公司 WANCO LIMITED
Product Code : BT508
Product Details

 Battery Analyzers


電池分析儀



Model : BT508


 

Fluke BT508 Battery Analyzers cover a broad range of battery test functions ranging from DC voltage and resistance tests to full condition testing using an automated string function testing and the test probe integrated infra-red temperature measurement system. 500 Series Battery Analyzers have been specifically designed for measurements on stationary batteries including GEL, AGM (Absorbed Glass MAT) and float open cells.

 

* Specification

Battery resistance

3 mΩ x 0.001 mΩ

30 mΩ x 0.01 mΩ

300 mΩ x 0.1 mΩ

3000 mΩ x 1 mΩ


 

Accuracy

1% + 8

0.8% + 6

0.8% + 6

0.8% + 6


 

Vdc

6 V x 0.001 v

60 V x 0.01 v0.01 v

600 V x 0.1 v

 

Accuracy

0.09% + 5

0.09% + 5

0.09% + 5

 

Meter mode

999 records for each measurement position with time stamp




Sequence mode

Up to 100 profiles and 100 profile templates (Each profile stores up to 450 batteries) with time stamp




1 The measurement is based on ac injection method. The injected source signal is < 100 mA, 1 kHz.

2 Trigger level VAC: 10 mV, Aac: 10 A




* Measurement Modes

Resistance (mΩ)

Battery voltage

Voltage dc

DMM mode

Memory view




* General Specifications

Size (HxWxD)

22 cm x 10.3 cm x 5.8 cm (9 in x 4 in x 2 in)

Weight

850 g (1.9 lb)

Screen dimensions

7.7 cm x 5.6 cm (3 in x 2.2 in)

Interface

USB mini

Warranty

3 years




* Environment Specifications

Operating temperature

0°C to 40°C

Storage temperature

-20°C to 50°C

Lithium-ion battery charging temperature

0°C to 40°C

Operating humidity

Non-condensing (10°C)

<=80% RH (at 10°C to 30°C)

<=75% RH (at 30°C to 40°C)

Operating altitude

Sea level to 2000 meters

Storage altitude

Sea level to 12,000 meters

IP rating

IP40

Radio

FCC Class A

Vibration requirements

MIL-PRF-28800F: Class 2

Drop test requirements 1 meter

Temperature coefficients

Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C




Safety compliance 600 V CAT III

EMC: IEC 61326

ROHS: China, Europe

Protection class 2: Pollution Degree II

Battery compliance

UN38.3

UL2054

IEC62133

2G per IEC68-2-26, 25G, and 29